1.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592942

ABSTRACT

Objective To make up the common X-ray examination methods of the shoulder joint and afford more medical inmormation for the radiologist and clinican. Methods More projection posture and angle were used to obtain more information of the shoulder joint. Results Y posture and outlet posture could afford more anatomy information than the traditional posture. It solved the problem of the overlap of different tissues in traditional X-ray examination. Conclusion Combinating the Y posture, outlet posture and A-P position projection is very important for X-ray examination of disease and injury of the shoulder joint.

2.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592934

ABSTRACT

Fierce earthquake could result in mass casualties. The patient is sent to the hospital after simple trauma management for further treatment. Emergency response to hospital infection management in station hospital can effectively prevent the occurrence and spreading of infectious diseases.

3.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592861

ABSTRACT

Objective To contrast the image qualities and the display percentage of vessel branches in cerebral angiography by two techniques, namely, Digital Subtraction CT Angiography (DSCTA) and Dual Energy Subtraction CT Angiography (DECTA). Methods 40 patients were divided averagely into Group A and Group B. All of them underwent head CTA exam, employing Somaton Definition Dual-Source CT of Siemens. The patients in Group A were under the mode of single tube and single energy by DSCTA, meanwhile the patients in Group B were under the mode of dual tube and dual energy by DECTA. Then the image quality of two groups and the display percentage of main vessels and branch were contrasted. Results 18 patients out of 20 in Group A succeeded in subtraction while 2 cases failed because of patients′ motion. The rate of success was 90%; 20 patients in Group B did subtraction successfully and the achievement ratio was 100%; there was no great difference on cerebral main vessels and branches which displayed in image between two groups. But the image quality of group A was superior to that of Group B. Conclusion As the development of dual-source CT′s hardware and software, DECTA Cerebral Angiography will be applied widely in clinic.

4.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592818

ABSTRACT

Objective To assess the clinical application value and advantages of DSCT Angiography on artery injury in Extremities. Methods Seven suspected patients with artery injury in extremities underwent DSCT Angiography, including three cases on artery injury of upper extremity and four cases on artery injury of lower extremity. All the seven patients were performed with DSCT Angiography after the operation. The data of thin slice cross section were reconstructed by MPR, MIP and VR, employing Somatom Definition, German. Contrast-concentration was 350 or 370mg i/ml, total amount was 80-100ml and injection rates was 4.0 ml/s. Results All the images of angiography displayed many clear blood vessels and smooth vessels verge, contrasting with surrounding issues well. They also displayed no ladder artifact or truncation artifact. The image quality was good enough to meet the requirements of clinical diagnosis. Meanwhile the coincidence between preoperative diagnosis and postoperative diagnosis was 100%. Conclusion To suspected patients with artery injury in extremities, DSCT Angiography may be the first choice. Three-dimensional reconstruction angiographys by means of different reconstruction techniques are very helpful in diagnosing and formulating treatment perscription.

5.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592814

ABSTRACT

Objective To use high and low condition to get contrast radiography of nasal bone photograph to raise the image quality. Methods 75 cases with nasal bone injury were adopted as the subjects. Results In 75 cases of nasal bone wound,93% could meet the demand. Conclusion Nasal bone side position photography in high and low codition can rasie the image quality and meet the clinical diagnosis demand in maxium degraee.

6.
Journal of Third Military Medical University ; (24)2003.
Article in Chinese | WPRIM | ID: wpr-555691

ABSTRACT

Objective To evaluate the clinical value of the oral contrast-enhanced three-dimensional spiral CT cholangiography to display better the intrahepatic and extrahepatic bile ducts. Methods Before spiral CT scanning, the preparation was similar to the conventional X-ray oral cholecystography. The collected parameters included 3-5 mm slice, 1 or 1.5 pitch, 120 kV, 220-250 mAs, and 1 mm reconstruction image. Volume rendering was used to construct the 3D bile duct images. Results In the 20 patients without serious biliary obstruction, oral three-dimensional CT cholangiography displayed the grade Ⅰ branch of hepatic ducts clearly and the displaying rate was 100%. The displaying of the grade Ⅱ branch of hepatic ducts was not good enough and the rate was 60%. The grade Ⅲ branch of hepatic ducts could not be displayed. Conclusion As the substitute and supplement of invasive ERCP, spiral CT 3D cholangiography is safe, simple, painless, and non-invasive. Furthermore, spiral CT 3D cholangiography can display the space structure of bile duct tree more clearly than ERCP. This technique is of great clinical value.

7.
Journal of Third Military Medical University ; (24)2002.
Article in Chinese | WPRIM | ID: wpr-565864

ABSTRACT

Objective To investigate the effects of tagged fluid and substraction in CT virtual colonoscopy (CTVC) on the conspicuity of polyps and to confirm the optimal attenuation value and the optimal viewing window. Methods Polyps measured 3-10 mm were created in fresh porcine colon in vitro and submerged in saline and mixed with positive contrast medium for the CT values of 200 HU, 400 Hu, 600 HU, and 800 HU. Polyps were measured before and after substraction and compared with those in the control group. The effects of different viewing windows and different attenuation values on the measurement and conspicuity of polyps were analyzed. Results The optimal attenuation value of tagged fluid was 800 HU and the optimal viewing window was colon (-150 HU, 1 500 HU) and bone (500 HU, 2 500 HU). Conclusion The combination of tagged fluid and CT substraction can improve the conspicuity of small polyps covered by colonic fluid.

8.
Chinese Journal of Hepatology ; (12): 362-365, 2002.
Article in Chinese | WPRIM | ID: wpr-276567

ABSTRACT

<p><b>OBJECTIVE</b>To explore and evaluate the effect of radio frequency ablation (RFA) in treatment of hepatic VX(2) tumor in rabbits.</p><p><b>METHODS</b>The hepatoma was treated with RFA in rabbits. The complete necrotic rate of the tumors, pathological changes, CT images and the animals' survival time were observed.</p><p><b>RESULTS</b>(1) ALT in serum increased significantly on the first day and decreased to the control level during 4th-7th day following RFA. (2) On the second week, CT scans showed that complete necrotic foci became larger, and the density of which was asymmetrical. Enhanced CT scans showed no obvious intensification inside; however, ringed intensification appeared along edges of the foci. Biopsy showed that the dark necrotic tissue was surrounded by ringed granulation tissue. Incomplete necrotic tumor foci resembled the complete necrotic foci in no enhanced CT images; however, asymmetrical intensification was observed in enhanced CT scans in the incomplete necrotic foci. Macroscopic observation showed irregular tumor tissue between the necrotic tissue and the peripheral normal tissue. Biopsy showed tumor recurrence in it. (3) Compared with the control, survival time of the animals was longer, and metastases rate in lungs and the fatality rate were lower in the treatment group.</p><p><b>CONCLUSIONS</b>RFA, with little injury, is an effective method in the treatment of hepatoma. Enhanced CT scans are consistent with pathological morphometrics of the tumor foci after RFA. The enhanced CT scan is a valuable check-up, which could be used to observe the therapeutic effect after RFA.</p>


Subject(s)
Animals , Rabbits , Carcinoma, Hepatocellular , Catheter Ablation , Liver Neoplasms , Diagnostic Imaging , General Surgery , Necrosis , Neoplasm Recurrence, Local , Radionuclide Imaging , Tomography, X-Ray Computed
9.
Journal of Third Military Medical University ; (24)1983.
Article in Chinese | WPRIM | ID: wpr-565112

ABSTRACT

Objective To compare the clinical value of 2 oral contrast agents for magnetic resonance cholangiopancreatography(MRCP)and to investigate the safety,potency ratio of negative gastrointestinal contrast agents and to improve MRCP image quality.Methods Before MRCP,30 patients took oral ferric ammonium citrate(FAC)solution as group A and another 30 patients took Gd-DTPA dilution as group B.Then all patients underwent MRCP with T2-haste-fs-thick-slab sequence.Image assessment was done before and after oral taking of negative gastrointestinal contrast agents.Results After oral taking of negative gastrointestinal contrast agents,the interference of liquid in stomach and duodenum was suppressed and even effectively eliminated on MRCP.MRCP image quality was improved.Though the display of bile duct and pancreatic duct was of less image artifact,it reached the quality for diagnosis.No significant difference of MRCP image quality was found between those took FAC solution or Gd-DTPA solution.Conclusion FAC and Gd-DTPA both are effective negative gastrointestinal contrast agents.Gd-DTPA solution is of better function and higher quality-price ratio.

SELECTION OF CITATIONS